Cyber Monday Special Sale - 70% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: best70

Page: 1 / 2
Total 18 questions
Exam Code: DES-1111                Update: Dec 5, 2025
Exam Name: Specialist - Technology Architect. PowerMax and VMAX All Flash Solutions Exam

EMC Specialist - Technology Architect. PowerMax and VMAX All Flash Solutions Exam DES-1111 Exam Dumps: Updated Questions & Answers (December 2025)

Question # 1

Data is being migrated from a VNX to a PowerMax using Open Replicator. The Pace Value is 0 with a Celling of 10%. Copies are taking a very long time to complete.

What could be done to resolve this issue?

A.

Set Pace to 10; set Ceiling to 0%

B.

Set Pace to 10; set Ceiling to 100%

C.

Leave Pace as-is; set Ceiling to None

D.

Leave Pace as-is; set Ceiling to 100%

Question # 2

What is required before a port can be disassociated from an FA emulation on a PowerMax?

A.

The port must not be a member of any Port Group

B.

The port must not belong to an RDF group

C.

All ports on the I/O module must be offline

D.

All ports associated with the FA emulation must be offline

Question # 3

An architect uses the following command to collect data from a HP-UX host when designing a solution in BCSD:

sar –d –b interval count >> hostname.sar.date.txt

What does the –b flag in the command represent?

A.

Block

B.

Binary

C.

Break

D.

Buffer

Question # 4

What needs to be created in BCSD to link multiple SRDF/A sessions?

A.

Composite Group

B.

Logical relationship

C.

Consistency Group

D.

MSC logical relationship

Question # 5

SRDF/A has been enabled between two PowerMax arrays. An extended loss of all RDF links occurs.

What is the state of the RDF pair after link connectivity is restored?

A.

Split

B.

Failed Over

C.

Suspended

D.

Partitioned

Question # 6

What is the maximum number of files that can be uploaded in a single operation in Sizer?

A.

10

B.

20

C.

30

D.

40

Question # 7

A storage architect is evaluating the performance of a PowerMax array during business hours. They want to know how much extra load the PowerMax can handle without significant performance degradation. The Workload Planner is used to identify the hot spots during the recurring backup windows.

Between 9:30 PM and 1:30 AM and between 3:15 AM and 5:30 AM, backups are causing the PowerMax to exceed the best practice recommendation. The Recurring System Data Exclusion Periods chart is used to filter out these hot spots. After running this workload planning for a few weeks, they notice that the selection of records they previously made are showing different numbers than when they started viewing the report, several weeks ago.

What is the explanation for this behavior?

A.

After a week the data of each time slot is refreshed with new data

B.

After two weeks the 84 data points are filled up and the report resets to default

C.

The average of the viewed window has dropped below the best practice

D.

After two weeks the data of each time slot is refreshed with new data

Question # 8

What happens to the space used for SnapVX delta tracks that are unique to a terminated snapshot?

A.

Not returned to SRP until the –force fag is used

B.

Not returned to SRP until all generations are terminated

C.

Returned to SRP only if it is mentioned explicitly

D.

Returned to the SRP by default

Question # 9

A very small data center is being deployed at a service provider site. New 32 GB FC switches to support Open Systems hosts have been purchased and installed in the data center. Two of the tenants for data storage are from competing small businesses. Data storage for each tenant is expected to be a maximum of 500 TB. Because tenants are from competing companies, the service provider wants to be able to provide data storage from different arrays to each tenant to guarantee separation of data and information.

Which array is recommended to support these requirements, while occupying the least amount of space in the new data center?

A.

PowerMax 8000

B.

VMAX All Flash 250

C.

VMAX All Flash 950

D.

PowerMax 2000

Question # 10

A customer is planning to purchase a PowerMax 8000 system with the zEssentials software package. The environment needs to have the ability to rapidly recover from large scale logical corruption using TimeFinder SnapVX.

Which optional software should be recommended to fulfill the requirement?

A.

Product Suite for z/TPF

B.

GDPR

C.

zDP

D.

AutoSwap

Page: 1 / 2
Total 18 questions

Most Popular Certification Exams

Payment

       

Contact us

dumpscollection live chat

Site Secure

mcafee secure

TESTED 05 Dec 2025