Summer Special Limited Time 65% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: dcdisc65

Page: 1 / 2
Total 19 questions
Exam Code: E20-562                Update: Oct 15, 2025
Exam Name: VPLEX Specialist Exam for Storage Administrators

EMC VPLEX Specialist Exam for Storage Administrators E20-562 Exam Dumps: Updated Questions & Answers (October 2025)

Question # 1

What is the correct order of steps to create a virtual volume?

Question # 2

How many copies can RecoverPoint maintain in a MetroPoint topology?

A.

4

B.

5

C.

6

D.

8

Question # 3

Using the Storage Volume expansion method for virtual volumes built on RAID-1 or distributed RAID-1 devices, what is the maximum number of initialization processes that can run concurrently, per cluster?

A.

100

B.

250

C.

500

D.

1000

Question # 4

Refer to the exhibit.

A virtual volume created on a distributed device is experiencing performance problems. The virtual volume is in a storage view in Cluster-1.

What could be the issue?

A.

There is storage volume contention on Cluster-2

B.

A WAN COM failure has occurred

C.

Distributed device I/O is exceeding WAN COM bandwidth

D.

Device mobility jobs are moving data across the WAN COM

Question # 5

What determines which cluster will service I/O in the event of a WAN COM failure for a distributed device that is not a member of a consistency group?

A.

Rule set of the distributed device

B.

VPLEX Witness

C.

Detach rule of the consistency group

D.

Detach rule of the storage view

Question # 6

How are physical ports numbered for each I/O module in VS6 VPLEX hardware?

A.

Director-A: 0 to 3 from the topDirector-B: 0 to 3 from the bottom

B.

Director-A: 1 to 4 from the bottomDirector-B: 1 to 4 from the top

C.

Director-A: 0 to 3 from the bottomDirector-B: 0 to 3 from the top

D.

Director-A: 1 to 4 from the topDirector-B:1 to 4 from the bottom

Question # 7

A service provider has implemented a VPLEX Metro cluster without VPLEX Witness and has implemented a static rule set. The static rule set has been set to “cluster-2 detaches”. A Microsoft Windows host in the Cluster-1 data center uses a distributed volume. However, the WAN COM fails.

What is the result of this failure?

A.

1. VPLEX suspends I/O to all distributed devices on both clusters2. VPLEX starts a delay timer3. If connectivity is not restored within the timer expiration period, VPLEX resumes I/O on Cluster-2 and keeps I/O suspended on Cluster-1.

B.

1. VPLEX starts a delay timer2. VPLEX suspends I/O to all distributed devices on both clusters3. If connectivity is not restored within the timer expiration period, VPLEX resumes I/O on Cluster-1 and keeps I/O suspended on Cluster-2.

C.

1. VPLEX suspends I/O to all distributed devices on both clusters2.VPLEX starts a delay timer3. If connectivity is not restored within the timer expiration period, VPLEX resumes I/O on Cluster-1 and keeps I/O suspended on Cluster-2.

D.

1. VPLEX starts a delay timer2. VPLEX suspends I/O to all distributed devices on both clusters3. If connectivity is not restored within the timer expiration period, VPLEX resumes I/O on Cluster-2 and keeps I/O suspended on Cluster-1.

Question # 8

When is expanding a virtual volume using the Storage Volume expansion method a valid option?

A.

Virtual volume previously expanded by adding extents or devices

B.

Virtual volume is mapped 1:1 to the underlying storage volume

C.

Virtual volume is a metadata volume

D.

Virtual volume has minor problems, as reported by health-check

Question # 9

Which type of statistics is used to track latencies, determine median, mode, percentiles, minimums, and maximums?

A.

Buckets

B.

Monitors

C.

Readings

D.

Counters

Question # 10

What can be used to monitor VPLEX performance parameters?

A.

VPLEX Cluster Witness

B.

Unisphere Performance Monitor Dashboard

C.

EMC SolVe Desktop

D.

EMCREPORTS utility

Page: 1 / 2
Total 19 questions

Most Popular Certification Exams

Payment

       

Contact us

dumpscollection live chat

Site Secure

mcafee secure