Pre-Winter Special Sale - 70% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: best70

Page: 1 / 3
Total 24 questions
Exam Code: 93-Tall-Mass-Timber-Buildings                Update: Oct 12, 2026
Exam Name: 93-Tall-Mass-Timber-Buildings

International Code Council 93-Tall-Mass-Timber-Buildings 93-Tall-Mass-Timber-Buildings Exam Dumps: Updated Questions & Answers (October 2026)

Question # 1

Disregarding footnotes, which of the following is true regarding fire-resistance ratings of building elements per the International Building Code Table 601?

A.

Type IV-A is the same as Type I-A

B.

Type IV-A is the same as Type II-A

C.

Type IV-C is the same as Type III-A

D.

Type IV-C is the same as Type IV-HT

Question # 2

A proprietary field-glued mass timber beam splice will require which of the following:

A.

Special inspection

B.

Approval from the permit applicant

C.

Field verification by the building official

D.

Field verification by the registered design professional

Question # 3

Periodic special inspection of sealants or adhesives shall be conducted where sealants or adhesives are part of a mass timber building element as designated in the approved construction documents.

All of the following statements are correct in reference to sealants or adhesives in mass timber buildings except:

A.

Sealants shall meet the requirements of ASTM C920.

B.

Adhesives shall meet the requirements of ASTM D3498.

C.

Special inspection of mass timber sealing requirements also apply to joints.

D.

Sealants at abutting edges and intersection of mass timber buildings need periodic inspections.

Question # 4

Refer to the exhibit by clicking on the EXHIBIT button above.

In the detail shown, which fasteners require fire protection according to AWC Technical Report 10?

A.

Those in the 2x2 block

B.

Those in the 2x10s

C.

Those in the gypsum filler

D.

The 1/2 in. lag screws attaching the steel ledger

Question # 5

In mass timber construction of Type IV-B, each of the following is suitable for use as fireblocking except:

A.

mineral wool.

B.

one-half-inch gypsum board.

C.

7/16-inch wood structural panels.

D.

mass timber complying with IBC Section 2304.11.

Question # 6

When Type X gypsum board is used as noncombustible protection over mass timber on the building ' s exterior walls, which of the following fasteners are permitted?

A.

Galvanized nails of minimum 12 Gage with a 7/16-inch head of sufficient length to penetrate the mass timber a minimum of 1 in.

B.

Galvanized nails of minimum 16 Gage with a 7/16-inch head of sufficient length to penetrate the mass timber a minimum of 1 in.

C.

Screws which comply with ASTM C 1002 (Type S, Type W, or Type G) of sufficient length to penetrate the mass timber a minimum of 3/4 in.

D.

Screws which comply with ASTM C 1002 (Type S, Type W, or Type G) of sufficient length to penetrate the mass timber a minimum of 7/8 in.

Question # 7

Where Type X gypsum board serves as noncombustible protection for interior surfaces of wall and ceiling assemblies, all of the following code provisions are correct except:

A.

Screws shall penetrate at least 1 in. into mass timber.

B.

Screws shall be spaced 12 in. on center in both directions.

C.

Panel edges of any layer shall be offset 18 inches from those of the previous layer.

D.

Panel edges of the base layer shall be taped and finished with joint compound.

Question # 8

Which of the following provisions for mass timber used for interior exit and elevator hoistway enclosures is true?

A.

Type IV-A construction requires at least 80 minutes of the 120-minute fire-resistance rating to be provided by noncombustible protection.

B.

Type IV-B construction requires at least 40 minutes of the 120-minute fire-resistance rating to be provided by noncombustible protection.

C.

Type IV-C construction requires at least 40 minutes of the 60-minute fire-resistance rating to be provided by noncombustible protection.

D.

Type IV-HT construction requires at least 40 minutes of the 60-minute fire-resistance rating to be provided by noncombustible protection.

Question # 9

Refer to the exhibit by clicking on the EXHIBIT button above.

In the detail shown and according to AWC Technical Report 10, what is the time assigned in minutes to 5/8 in. Type X gypsum board for connection fire protection thermal separation requirements?

A.

Both layers = 20

B.

Both layers = 40

C.

Layer adjacent to the connection = 20 and second layer = 40

D.

Layer adjacent to the connection = 40 and second layer = 20

Question # 10

The International Building Code requires cross-laminated timber (CLT) to be manufactured and identified in accordance with which standard?

A.

PRG 320

B.

DOC PS 2

C.

AITC A190.1

D.

ASTM D 5055

Page: 1 / 3
Total 24 questions

Most Popular Certification Exams

Payment

       

Contact us

Site Secure

mcafee secure

TESTED 12 Oct 2026