Summer Special Limited Time 65% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: dcdisc65

Page: 1 / 3
Total 23 questions
Exam Code: NCSC-Level-1                Update: Jun 9, 2025
Exam Name: Nutanix Certified Services Consultant (NCSC): Level 1

Nutanix Nutanix Certified Services Consultant (NCSC): Level 1 NCSC-Level-1 Exam Dumps: Updated Questions & Answers (June 2025)

Question # 1

A consultant notices while assigning VLAN tags to hosts and CVMs in a running cluster, that Prism Element displays alerts indicating a node is down.

What should the consultant do to prevent these alerts?

A.

Restart the Nutanix cluster.

B.

Only change the Controller Virtual Machine VLANs.

C.

Only change the hypervisor VLANs.

D.

Stop the Nutanix cluster before changing VLANs.

Question # 2

Refer to the exhibits.

A consultant is trying to test port failover on the node shown in the first exhibit. A continuous ping test is performed to the host. The consultant shuts down one of the links, after which the host ping request times out. The consultant tries to troubleshoot the issue with the customer and sees the information shown in the second exhibit on their Cisco Switches:

What is causing the issue?

A.

There is a Native VLAN mismatch on the switchport.

B.

The wrong VLAN is tagged on the host.

C.

Bad SPF+ cables are on the active interface.

D.

PortFast is not enabled on the port connected to the host.

Question # 3

A consultant is running the Foundation VM using desktop virtualization software. No nodes are discovered.

What should the consultant verify first?

A.

NAT

B.

Host-only Adapter

C.

Bridged Adapter

D.

Internal Network

Question # 4

Refer to the exhibit.

A consultant is deploying a cluster using the customer-provided IP addressing information.

Which option in Foundation must be configured to ensure connectivity during the deployment?

A.

Link Aggregation

B.

Range Autofill

C.

Network Segmentation

D.

Multi-homing

Question # 5

Which subnet is reserved for internal connectivity within a Nutanix Cluster?

A.

192.168.5.0/24

B.

192.168.254.0/24

C.

192.168.5.0/23

D.

192.168.5.0/26

Question # 6

During a technical call with a customer, it is identified that this installation will be software only on Dell servers. The out-of-band management interfaces will not be given IP addresses until the consultant is onsite.

Which Foundation method should be used for this type of installation?

A.

Bare metal using iDRAC MAC addresses.

B.

Bare metal using LAN MAC addresses.

C.

Bare metal using block serial numbers.

D.

Bare metal using node serial numbers.

Question # 7

A consultant is preparing to foundation over a customer network that has the following criteria:

* VLAN segmented network

* VLAN tags on the nodes must be imaged prior to starting the foundation process.

For each node, the consultant has done the following:

* Connected to the Network Crash Cart of the Node

* Logged in using “root” credentials

What should the consultant do next?

A.

1. CD to /root/nutanix-network-crashcart/

2. Start Network Utility tool by running: ./network_configuration

3. Change Values

B.

1. CD to /home/data/nutanix/nutanix-network-crashcart/

2. Start Network Utility tool by running: ./network_configuration

3. Change Values

C.

1. Log into CVM using nutanix@192.168.5.254

2. CD to /root/Nutanix-network-crashcart/

3. Start Network Utility tool by running: ./network_configuration

4. Change Values

D.

1. Log into CVM using nutanix@192.168.5.254

2. CD to /home/data/nutanix/nutanix-network-crashcart/

3. Start Network Utility tool by running: ./network_configuration

4. Change Values

Question # 8

A consultant is running Foundation. The cluster creation fails during the process. The host logs confirm that the nodes have been successfully imaged. The consultant decides to create the cluster manually.

Which command should the consultant use?

A.

cluster -c IP_CVM_A, IP_CVM_B, IP_CVM_n

B.

cluster create -s IP_CVM_A, IP_CVM_B, IP_CVM_n

C.

cluster -s IP_CVM_A, IP_CVM_B, IP_CVM_n create_manual

D.

cluster -s IP_CVM_M, IP_CVM_B, IP_CVM_n create

Question # 9

A customer wants to expand an existing cluster with three additional nodes. After running the Foundation process on the new nodes, the customer realizes that the wrong IPs where used and the nodes are configured on a different network. The customer decides to create a new cluster instead.

Which method should be used to recreate the cluster?

A.

Log into IPMI and use cluster create command to create the cluster.

B.

Log into CVM and use cluster create command to create the cluster.

C.

Log into Hypervisor and use cluster create command to create the cluster.

D.

Foundation all nodes again and create the cluster.

Question # 10

A consultant deploys a four-node VMware ESXi cluster and vCenter server. An HA/DRS cluster is configured for all four nodes. The customer deploys five new VMs on the cluster.

During the knowledge Transfer, a network cable on one node is removed to demonstrate HA and migration of the VMs to another host. In the HA/DRS cluster settings, the VM Restart Priority for all CVMs is set to Disabled. The customer observes warnings that the CVM on the ejected host is no longer powered on.

Which ESXi HA/DRS cluster setting is missing?

A.

Enable EVC for the cluster.

B.

Disable VM Monitoring on all CVMs.

C.

Disable Automation Level on all CVMs.

D.

Enable Host Monitoring.

Page: 1 / 3
Total 23 questions

Most Popular Certification Exams

Payment

       

Contact us

dumpscollection live chat

Site Secure

mcafee secure

TESTED 19 Jun 2025