What is the required PSU wattage for a FlashArray// X70R2/R3 or X90R2/R3 array?

A.

1200W

B.

1300W

C.

1600W

Question # 2

An Implementation Engineer performs a controller upgrade. What command should the Implementation Engineer run to check I/O health?

A.

purehost monitor --balance

B.

purehost list --all

C.

pureport list --initiator

Question # 3

Once the new Purity firmware has been installed using the pureinstall command, what step is required to commit the new version?

A.

Log out of the controller

B.

Reboot the controller

C.

Reboot the array

Question # 4

On FlashArray models that use standard DFMs instead of DFMDs, which NVRAM bays are always populated?

A.

NVB0 and NVB1

B.

NVB0 and NVB2

C.

NVB0 and NVB3

D.

NVB1 and NVB2

Question # 5

What is the speed of the Ethernet ports to connect a FlashArray //E to a DFS?

A.

40G

B.

25G

C.

100G

Question # 6

An Implementation Engineer is performing a FlashArray//XR4 to FlashArray//XL upgrade, and is preparing to remove the XR4 CT0 controller. Which command should the Implementation Engineer run to stop Purity after confirming CT0 is the secondary controller?

A.

purewes controller disable --purity --verify-mode secondary --verify-array ARRAY_NAME ct0

B.

purewes controller disable --purity --verify-mode primary --verify-array ARRAY_NAME ct0

C.

purewes controller setattr --disable --verify-mode secondary --verify-array ARRAY_NAME ct0

Question # 7

An Implementation Engineer is upgrading a FlashArray//X50R3 to an //X50R4. The array has 10 SAS and 10 DirectFlash modules in the chassis.

What type of controller is required to complete the upgrade?

A.

FLASHARRAY//X50 R4, SE

B.

FLASHARRAY//X50 R4, NS

C.

FLASHARRAY//X50 R4, Base

D.

FLASHARRAY//X50 R4, NVMe

Question # 8

When adding a data pack into a FlashArray chassis or a DFS shelf, the drives show "unrecognized" status when running puredrive list.

What is the cause of this status on the newly inserted drives?

A.

The Purity version of the FlashArray/DFS is incompatible with the new drives.

B.

The drives exceed the max space supported for the controller model.

C.

There is a hardware fault that needs to be corrected.

D.

The drives have not yet been logically admitted into the array.

Question # 9

An Implementation Engineer attempts to add a FlashArray to a Fusion fleet but receives an error indicating the array cannot be added. The array appears healthy and is connected to Pure1. What is the most likely cause of this issue?

A.

The array does NOT have any existing workloads configured.

B.

The array is already assigned to another Fusion fleet.

C.

The array is NOT running the latest Purity//FA version.

Question # 10

Which FlashArray//XL DirectMemory Modules (DMMs) configuration condition is true?

A.

DMMs are only compatible with //XL 170.

B.

DMMs cannot be installed in a DirectFlash Shelf (DFS).

C.

DMMs use different drive slots to regular DirectFlash modules.